Eaton HCM1A0503V3-R75-R 0.75 uH AEC-Q200 Inductor, 10 A
Eaton HCM1A0503V3-R75-R 0.75 uH AEC-Q200 Inductor, 10 A

Eaton HCM1A0503V3-R75-R 0.75 uH AEC-Q200 Inductor, 10 A

Share
Eaton HCM1A0503V3-R75-R: AEC-Q200 automotive power inductor, 0.75 uH ±20%, 10 A Irms, Isat 11.5 A, DCR 7 mOhm, 5.7 x 5.4 mm.
    • Product Details
    • Download

    Eaton HCM1A0503V3-R75-R 0.75 uH AEC-Q200 Inductor, 10 A

    HCM1A0503V3-R75-R at a glance: AEC-Q200 automotive power inductor, 0.75 uH ±20%, 10 A Irms, Isat 11.5 A (20% rolloff @ +25 °C), DCR 7 mOhm, 5.7 x 5.4 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCM1A0503V3-R75-R
    OCL (open circuit inductance)0.75 uH ±20%
    FLL minimum, at Isat0.48 uH
    Irms (DC, 40 °C rise)10 A
    Isat (20% rolloff @ +25 °C)11.5 A
    DCR typical @ +20 °C7 mOhm
    DCR maximum @ +20 °C8.1 mOhm
    SRF typical57 MHz
    K-factor (Bp-p = K x L x dI)687, Bp-p in Gauss
    Package5.7 x 5.4 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1483

    Mechanical Dimensions & Pad Layout

    HCM1A0503V3-R75-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1483: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    At the rated 10 A the winding dissipates about 0.7 W in copper alone, using the typical DCR of 7 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Stored energy at Isat is about 49.6 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    With K = 687, a peak-to-peak ripple of one amp produces roughly 515 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 57 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    What This Family Is For

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    In the HCM1A0503V3 line-up this part is number 7 of 15 by inductance, between 0.2 uH and 10 uH.

    One step down the table, HCM1A0503V3-R68-R, sits at 0.68 uH with 10 A and 6.9 mOhm – the lower inductance buys about 1.6 A of extra current in the same body.

    • Core material: alloy powder core, 5.7 x 5.4 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 8.1 mOhm becomes roughly 12.4 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Verify the part marking for revision traceability in production.
    • Verify the part marking for revision traceability in production.
    • Confirm the qualification file covers the module-level test plan.

    Frequently Asked Questions

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products