| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0703-1R2-R |
| OCL (open circuit inductance) | 1.2 uH ±20% |
| FLL minimum, at Isat | 0.76 uH |
| Irms (DC, 40 °C rise) | 7.8 A |
| Isat (20% rolloff @ +25 °C) | 11 A |
| DCR typical @ +20 °C | 9.3 mOhm |
| DCR maximum @ +20 °C | 10.2 mOhm |
| K-factor (Bp-p = K x L x dI) | 446, Bp-p in Gauss |
| Package | 7.4 x 7 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10548 |

Drawing reproduced from Eaton Technical Data 10548: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.
At the rated 7.8 A the winding dissipates about 0.566 W in copper alone, using the typical DCR of 9.3 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
Stored energy at Isat is about 72.6 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
The K-factor of 446 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 535 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Of the 19 values listed for HCM1A0703, this is the 10th, in a family covering 0.1 uH to 33 uH.
The next value up in the same family, HCM1A0703-2R2-R, gives 2.2 uH at 5.7 A and DCR 18 mOhm: the extra inductance costs about 2.2 A of rated current.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 10.2 mOhm becomes roughly 15.6 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
What does AEC-Q200 cover?
The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd