| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0703-R10-R |
| OCL (open circuit inductance) | 0.10 uH ±20% |
| FLL minimum, at Isat | 0.06 uH |
| Irms (DC, 40 °C rise) | 22 A |
| Isat (20% rolloff @ +25 °C) | 28 A |
| DCR typical @ +20 °C | 1.2 mOhm |
| DCR maximum @ +20 °C | 1.4 mOhm |
| K-factor (Bp-p = K x L x dI) | 2,737, Bp-p in Gauss |
| Package | 7.4 x 7 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10548 |

Drawing reproduced from Eaton Technical Data 10548: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.
Copper loss at the rated current works out to roughly 0.581 W from a typical DCR of 1.2 mOhm at 22 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
Stored energy at Isat is about 39.2 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
The K-factor of 2,737 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 274 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
The HCM1A0703 family spans 0.1 uH to 33 uH; this row sits at position 1 of 19.
Compared with its neighbours in the table, HCM1A0703-R15-R trades 0 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 1.4 mOhm becomes roughly 2.14 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What is the operating temperature range?
The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.
What does AEC-Q200 cover?
The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.
What does AEC-Q200 cover?
The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.
Shenzhen Gaorunxin Technology Co., Ltd