| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0703-R82-R |
| OCL (open circuit inductance) | 0.82 uH ±20% |
| FLL minimum, at Isat | 0.52 uH |
| Irms (DC, 40 °C rise) | 8.5 A |
| Isat (20% rolloff @ +25 °C) | 14 A |
| DCR typical @ +20 °C | 6.7 mOhm |
| DCR maximum @ +20 °C | 8 mOhm |
| K-factor (Bp-p = K x L x dI) | 482, Bp-p in Gauss |
| Package | 7.4 x 7 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10548 |

Drawing reproduced from Eaton Technical Data 10548: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.
At the rated 8.5 A the winding dissipates about 0.484 W in copper alone, using the typical DCR of 6.7 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
Stored energy at Isat is about 80.4 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
K-factor 482 means the flux swing is about 395 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Of the 19 values listed for HCM1A0703, this is the 8th, in a family covering 0.1 uH to 33 uH.
Compared with its neighbours in the table, HCM1A0703-1R0-R trades 2.1 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 8 mOhm becomes roughly 12.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.