Eaton HCM1A0703V2-150-R 15 uH AEC-Q200 Inductor, 2.6 A
Eaton HCM1A0703V2-150-R 15 uH AEC-Q200 Inductor, 2.6 A

Eaton HCM1A0703V2-150-R 15 uH AEC-Q200 Inductor, 2.6 A

Share
Eaton HCM1A0703V2-150-R: AEC-Q200 automotive power inductor, 15 uH ±20%, 2.6 A Irms, Isat 3.6 A, DCR 96 mOhm, 7.3 x 6.8 mm.
    • Product Details
    • Download

    Eaton HCM1A0703V2-150-R 15 uH AEC-Q200 Inductor, 2.6 A

    HCM1A0703V2-150-R at a glance: AEC-Q200 automotive power inductor, 15 uH ±20%, 2.6 A Irms, Isat 3.6 A (20% rolloff @ +25 °C), DCR 96 mOhm, 7.3 x 6.8 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1A0703V2-150-R
    OCL (open circuit inductance)15 uH ±20%
    FLL minimum, at Isat9.6 uH
    Irms (DC, 40 °C rise)2.6 A
    Isat (20% rolloff @ +25 °C)3.6 A
    DCR typical @ +20 °C96 mOhm
    DCR maximum @ +20 °C110 mOhm
    SRF typical9.5 MHz
    K-factor (Bp-p = K x L x dI)147, Bp-p in Gauss
    Package7.3 x 6.8 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10911

    Outline Drawing

    HCM1A0703V2-150-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10911: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.

    At the rated 2.6 A the winding dissipates about 0.649 W in copper alone, using the typical DCR of 96 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    At Isat the part holds about 97.2 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    K-factor 147 means the flux swing is about 2,205 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Self-resonant frequency is 9.5 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    What This Family Is For

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A0703V2 family this is value 18 of 20, in a range that runs from 0.1 uH to 33 uH.

    One step down the table, HCM1A0703V2-100-R, sits at 10 uH with 3.3 A and 65 mOhm – the lower inductance buys about 1.3 A of extra current in the same body.

    • Core material: alloy powder core, 7.3 x 6.8 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 110 mOhm becomes roughly 168 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check the hot-corner saturation margin against the worst-case load step.
    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Verify the qualification and the mounting process match the assembly line.

    Frequently Asked Questions

    Why do V2 and V3 parts exist?
    They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.