Eaton HCM1A0703V3-150-R 15 uH AEC-Q200 Inductor, 2.6 A
Eaton HCM1A0703V3-150-R 15 uH AEC-Q200 Inductor, 2.6 A

Eaton HCM1A0703V3-150-R 15 uH AEC-Q200 Inductor, 2.6 A

Share
Eaton HCM1A0703V3-150-R: AEC-Q200 automotive power inductor, 15 uH ±20%, 2.6 A Irms, Isat 3.6 A, DCR 96 mOhm, 7.3 x 6.8 mm.
    • Product Details
    • Download

    Eaton HCM1A0703V3-150-R 15 uH AEC-Q200 Inductor, 2.6 A

    HCM1A0703V3-150-R at a glance: AEC-Q200 automotive power inductor, 15 uH ±20%, 2.6 A Irms, Isat 3.6 A (20% rolloff @ +25 °C), DCR 96 mOhm, 7.3 x 6.8 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCM1A0703V3-150-R
    OCL (open circuit inductance)15 uH ±20%
    FLL minimum, at Isat9.6 uH
    Irms (DC, 40 °C rise)2.6 A
    Isat (20% rolloff @ +25 °C)3.6 A
    DCR typical @ +20 °C96 mOhm
    DCR maximum @ +20 °C110 mOhm
    SRF typical9.5 MHz
    K-factor (Bp-p = K x L x dI)151, Bp-p in Gauss
    Package7.3 x 6.8 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1484

    Dimensions and Pad Layout

    HCM1A0703V3-150-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1484: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    The DCR figure of 96 mOhm is what sets the efficiency: at 2.6 A the winding drops about 0.25 mV and dissipates 0.649 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    At Isat the part holds about 97.2 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    With K = 151, a peak-to-peak ripple of one amp produces roughly 2,265 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 9.5 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Positioning in the Range

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Of the 20 values listed for HCM1A0703V3, this is the 18th, in a family covering 0.1 uH to 33 uH.

    Compared with its neighbours in the table, HCM1A0703V3-220-R trades 1.3 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: alloy powder core, 7.3 x 6.8 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 110 mOhm becomes roughly 168 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Confirm the qualification file covers the module-level test plan.
    • Confirm the qualification file covers the module-level test plan.

    Frequently Asked Questions

    Why do V2 and V3 parts exist?
    They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products