| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0703V3-1R2-R |
| OCL (open circuit inductance) | 1.2 uH ±20% |
| FLL minimum, at Isat | 0.76 uH |
| Irms (DC, 40 °C rise) | 9 A |
| Isat (20% rolloff @ +25 °C) | 12 A |
| DCR typical @ +20 °C | 8.6 mOhm |
| DCR maximum @ +20 °C | 9.9 mOhm |
| SRF typical | 35 MHz |
| K-factor (Bp-p = K x L x dI) | 449, Bp-p in Gauss |
| Package | 7.3 x 6.8 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1484 |

Drawing reproduced from Eaton Technical Data ELX1484: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.
The DCR figure of 8.6 mOhm is what sets the efficiency: at 9 A the winding drops about 0.077 mV and dissipates 0.697 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
At Isat the part holds about 86.4 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
With K = 449, a peak-to-peak ripple of one amp produces roughly 539 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
Self-resonant frequency is 35 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
The HCM1A0703V3 family spans 0.1 uH to 33 uH; this row sits at position 10 of 20.
The next value up in the same family, HCM1A0703V3-1R5-R, gives 1.5 uH at 8.5 A and DCR 9.5 mOhm: the extra inductance costs about 1.5 A of rated current.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 9.9 mOhm becomes roughly 15.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What does AEC-Q200 cover?
The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd