| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0805V2-100-R |
| OCL (open circuit inductance) | 10 uH ±20% |
| FLL minimum, at Isat | 6.4 uH |
| Irms (DC, 40 °C rise) | 4 A |
| Isat (20% rolloff @ +25 °C) | 6.2 A |
| DCR typical @ +20 °C | 49 mOhm |
| DCR maximum @ +20 °C | 60 mOhm |
| SRF typical | 12 MHz |
| K-factor (Bp-p = K x L x dI) | 61, Bp-p in Gauss |
| Package | 8.4 x 8 mm |
| Height | 5.4 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10902 |

Drawing reproduced from Eaton Technical Data 10902: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.
With 49 mOhm typical, the I-squared-R loss at the full 4 A rating is about 0.784 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
Stored energy at Isat is about 192 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
The K-factor of 61 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 610 Gauss of Bp-p, the figure the core-loss curve is plotted against.
Self-resonant frequency is 12 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
In the HCM1A0805V2 line-up this part is number 8 of 12 by inductance, between 0.22 uH and 47 uH.
The next value up in the same family, HCM1A0805V2-150-R, gives 15 uH at 4 A and DCR 43 mOhm: the extra inductance costs about 4 A of rated current.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 60 mOhm becomes roughly 91.8 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What is the operating temperature range?
The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
What does AEC-Q200 cover?
The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd