| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0805V2-4R7-R |
| OCL (open circuit inductance) | 4.7 uH ±20% |
| FLL minimum, at Isat | 3 uH |
| Irms (DC, 40 °C rise) | 8 A |
| Isat (20% rolloff @ +25 °C) | 8 A |
| DCR typical @ +20 °C | 13 mOhm |
| DCR maximum @ +20 °C | 15.6 mOhm |
| SRF typical | 15 MHz |
| K-factor (Bp-p = K x L x dI) | 122, Bp-p in Gauss |
| Package | 8.4 x 8 mm |
| Height | 5.4 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10902 |

Drawing reproduced from Eaton Technical Data 10902: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.
Copper loss at the rated current works out to roughly 0.832 W from a typical DCR of 13 mOhm at 8 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
Stored energy at Isat is about 150 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
K-factor 122 means the flux swing is about 573 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
Self-resonant frequency is 15 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Of the 12 values listed for HCM1A0805V2, this is the 7th, in a family covering 0.22 uH to 47 uH.
The next value up in the same family, HCM1A0805V2-100-R, gives 10 uH at 4 A and DCR 49 mOhm: the extra inductance costs about 5.2 A of rated current.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 15.6 mOhm becomes roughly 23.9 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What is the operating temperature range?
The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.
What is the operating temperature range?
The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd