| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1104-R56-R |
| OCL (open circuit inductance) | 0.56 uH ±20% |
| FLL minimum, at Isat | 0.36 uH |
| Irms (DC, 40 °C rise) | 22.5 A |
| Isat (20% rolloff @ +25 °C) | 24 A |
| DCR typical @ +20 °C | 1.56 mOhm |
| DCR maximum @ +20 °C | 1.8 mOhm |
| K-factor (Bp-p = K x L x dI) | 453, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10550 |

Drawing reproduced from Eaton Technical Data 10550: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.
Copper loss at the rated current works out to roughly 0.79 W from a typical DCR of 1.56 mOhm at 22.5 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
The core stores roughly 161 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
The K-factor of 453 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 254 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Of the 19 values listed for HCM1A1104, this is the 5th, in a family covering 0.2 uH to 100 uH.
The next value up in the same family, HCM1A1104-R90-R, gives 0.90 uH at 20 A and DCR 2.17 mOhm: the extra inductance costs about 8.5 A of rated current.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 1.8 mOhm becomes roughly 2.75 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.