    HCM1A1104V3-R56-R at a glance: AEC-Q200 automotive power inductor, 0.56 uH ±20%, 22.5 A Irms, Isat 24 A (20% rolloff @ +25 °C), DCR 1.56 mOhm, 11.2 x 10.3 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1A1104V3-R56-R
    OCL (open circuit inductance)0.56 uH ±20%
    FLL minimum, at Isat0.36 uH
    Irms (DC, 40 °C rise)22.5 A
    Isat (20% rolloff @ +25 °C)24 A
    DCR typical @ +20 °C1.56 mOhm
    DCR maximum @ +20 °C1.8 mOhm
    SRF typical62 MHz
    K-factor (Bp-p = K x L x dI)422, Bp-p in Gauss
    Package11.2 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1490

    Outline Drawing

    HCM1A1104V3-R56-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1490: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    This is the automotive version of the molded high-current inductor. The body is a molded powder core, the winding is shielded by the magnetic material itself, and the operating range runs to +155 °C. It is the part that goes on the DC-DC stages of body electronics, ADAS modules and infotainment head units.

    The DCR figure of 1.56 mOhm is what sets the efficiency: at 22.5 A the winding drops about 0.035 mV and dissipates 0.79 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    At Isat the part holds about 161 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    With K = 422, a peak-to-peak ripple of one amp produces roughly 236 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 62 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Positioning in the Range

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    In the HCM1A1104V3 line-up this part is number 5 of 19 by inductance, between 0.2 uH and 68 uH.

    The next value up in the same family, HCM1A1104V3-R90-R, gives 0.90 uH at 20 A and DCR 2.17 mOhm: the extra inductance costs about 5 A of rated current.

    • Core material: alloy powder core, 11.2 x 10.3 mm body at 4.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 1.8 mOhm becomes roughly 2.75 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Verify the qualification and the mounting process match the assembly line.
    • Verify the part marking for revision traceability in production.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.

    Frequently Asked Questions

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.