Eaton HCM1A1305-2R2-R AEC-Q200 Inductor 2.2 uH, Isat 18 A
Eaton HCM1A1305-2R2-R AEC-Q200 Inductor 2.2 uH, Isat 18 A

Eaton HCM1A1305-2R2-R AEC-Q200 Inductor 2.2 uH, Isat 18 A

Share
Eaton HCM1A1305-2R2-R: AEC-Q200 automotive power inductor, 2.2 uH ±20%, 15 A Irms, Isat 18 A, DCR 4.6 mOhm, 13.8 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCM1A1305-2R2-R AEC-Q200 Inductor 2.2 uH, Isat 18 A

    HCM1A1305-2R2-R at a glance: AEC-Q200 automotive power inductor, 2.2 uH ±20%, 15 A Irms, Isat 18 A (20% rolloff @ +25 °C), DCR 4.6 mOhm, 13.8 x 12.5 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A1305-2R2-R
    OCL (open circuit inductance)2.2 uH ±20%
    FLL minimum, at Isat1.41 uH
    Irms (DC, 40 °C rise)15 A
    Isat (20% rolloff @ +25 °C)18 A
    DCR typical @ +20 °C4.6 mOhm
    DCR maximum @ +20 °C5.29 mOhm
    K-factor (Bp-p = K x L x dI)153, Bp-p in Gauss
    Package13.8 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10551

    Mechanical Drawing

    HCM1A1305-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10551: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    This is the automotive version of the molded high-current inductor. The body is a molded powder core, the winding is shielded by the magnetic material itself, and the operating range runs to +155 °C. It is the part that goes on the DC-DC stages of body electronics, ADAS modules and infotainment head units.

    At the rated 15 A the winding dissipates about 1.03 W in copper alone, using the typical DCR of 4.6 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Stored energy at Isat is about 356 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    K-factor 153 means the flux swing is about 337 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Where This Series Fits

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    In the HCM1A1305 line-up this part is number 11 of 23 by inductance, between 0.1 uH and 33 uH.

    One step down the table, HCM1A1305-1R8-R, sits at 1.8 uH with 16 A and 4 mOhm – the lower inductance buys about 4 A of extra current in the same body.

    • Core material: alloy powder core, 13.8 x 12.5 mm body at 5.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 5.29 mOhm becomes roughly 8.1 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check the hot-corner saturation margin against the worst-case load step.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Check the hot-corner saturation margin against the worst-case load step.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products