| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1305-R33-R |
| OCL (open circuit inductance) | 0.33 uH ±20% |
| FLL minimum, at Isat | 0.21 uH |
| Irms (DC, 40 °C rise) | 35 A |
| Isat (20% rolloff @ +25 °C) | 44 A |
| DCR typical @ +20 °C | 0.8 mOhm |
| DCR maximum @ +20 °C | 0.92 mOhm |
| K-factor (Bp-p = K x L x dI) | 379, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10551 |

Drawing reproduced from Eaton Technical Data 10551: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.
The DCR figure of 0.8 mOhm is what sets the efficiency: at 35 A the winding drops about 0.028 mV and dissipates 0.98 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
Stored energy at Isat is about 319 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
K-factor 379 means the flux swing is about 125 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Of the 23 values listed for HCM1A1305, this is the 3th, in a family covering 0.1 uH to 33 uH.
Compared with its neighbours in the table, HCM1A1305-R47-R trades 7 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 0.92 mOhm becomes roughly 1.41 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What does AEC-Q200 cover?
The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd