Eaton HCM1A1305V2-2R2-R 2.2 uH Automotive Power Inductor
Eaton HCM1A1305V2-2R2-R 2.2 uH Automotive Power Inductor

Eaton HCM1A1305V2-2R2-R 2.2 uH Automotive Power Inductor

Share
Eaton HCM1A1305V2-2R2-R: AEC-Q200 automotive power inductor, 2.2 uH ±20%, 15 A Irms, Isat 25 A, DCR 4.04 mOhm, 13.8 x 12.9 mm.
    • Product Details
    • Download

    Eaton HCM1A1305V2-2R2-R 2.2 uH Automotive Power Inductor

    HCM1A1305V2-2R2-R at a glance: AEC-Q200 automotive power inductor, 2.2 uH ±20%, 15 A Irms, Isat 25 A (20% rolloff @ +25 °C), DCR 4.04 mOhm, 13.8 x 12.9 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A1305V2-2R2-R
    OCL (open circuit inductance)2.2 uH ±20%
    FLL minimum, at Isat1.41 uH
    Irms (DC, 40 °C rise)15 A
    Isat (20% rolloff @ +25 °C)25 A
    DCR typical @ +20 °C4.04 mOhm
    DCR maximum @ +20 °C4.65 mOhm
    SRF typical25 MHz
    K-factor (Bp-p = K x L x dI)118, Bp-p in Gauss
    Package13.8 x 12.9 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10904

    Outline Drawing

    HCM1A1305V2-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10904: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    With 4.04 mOhm typical, the I-squared-R loss at the full 15 A rating is about 0.909 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Energy storage at the saturation current is around 688 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The K-factor of 118 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 260 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Self-resonant frequency is 25 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Positioning in the Range

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    The HCM1A1305V2 family spans 0.1 uH to 33 uH; this row sits at position 11 of 23.

    One step down the table, HCM1A1305V2-1R8-R, sits at 1.8 uH with 17 A and 3.25 mOhm – the lower inductance buys about 5 A of extra current in the same body.

    • Core material: alloy powder core, 13.8 x 12.9 mm body at 5.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 4.65 mOhm becomes roughly 7.12 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check the hot-corner saturation margin against the worst-case load step.
    • Check the hot-corner saturation margin against the worst-case load step.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.

    Frequently Asked Questions

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    Why do V2 and V3 parts exist?
    They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.