| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1305V2-8R2-R |
| OCL (open circuit inductance) | 8.2 uH ±20% |
| FLL minimum, at Isat | 5.25 uH |
| Irms (DC, 40 °C rise) | 7.5 A |
| Isat (20% rolloff @ +25 °C) | 13 A |
| DCR typical @ +20 °C | 16 mOhm |
| DCR maximum @ +20 °C | 18.5 mOhm |
| SRF typical | 9 MHz |
| K-factor (Bp-p = K x L x dI) | 59, Bp-p in Gauss |
| Package | 13.8 x 12.9 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10904 |

Drawing reproduced from Eaton Technical Data 10904: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.
With 16 mOhm typical, the I-squared-R loss at the full 7.5 A rating is about 0.9 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
At Isat the part holds about 693 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
K-factor 59 means the flux swing is about 484 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
Self-resonant frequency is 9 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
In the HCM1A1305V2 line-up this part is number 18 of 23 by inductance, between 0.1 uH and 33 uH.
The next value up in the same family, HCM1A1305V2-100-R, gives 10 uH at 7.5 A and DCR 18.2 mOhm: the extra inductance costs about 0.1 A of rated current.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 18.5 mOhm becomes roughly 28.3 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd