Eaton HCM1A1305V2-R33-R 0.33 uH Automotive Power Inductor
Eaton HCM1A1305V2-R33-R 0.33 uH Automotive Power Inductor

Eaton HCM1A1305V2-R33-R 0.33 uH Automotive Power Inductor

Share
Eaton HCM1A1305V2-R33-R: AEC-Q200 automotive power inductor, 0.33 uH ±20%, 46 A Irms, Isat 50 A, DCR 0.59 mOhm, 13.8 x 12.9 mm.
    • Product Details
    • Download

    Eaton HCM1A1305V2-R33-R 0.33 uH Automotive Power Inductor

    HCM1A1305V2-R33-R at a glance: AEC-Q200 automotive power inductor, 0.33 uH ±20%, 46 A Irms, Isat 50 A (20% rolloff @ +25 °C), DCR 0.59 mOhm, 13.8 x 12.9 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1A1305V2-R33-R
    OCL (open circuit inductance)0.33 uH ±20%
    FLL minimum, at Isat0.21 uH
    Irms (DC, 40 °C rise)46 A
    Isat (20% rolloff @ +25 °C)50 A
    DCR typical @ +20 °C0.59 mOhm
    DCR maximum @ +20 °C0.69 mOhm
    SRF typical70 MHz
    K-factor (Bp-p = K x L x dI)345, Bp-p in Gauss
    Package13.8 x 12.9 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10904

    Outline Drawing

    HCM1A1305V2-R33-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10904: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.

    At the rated 46 A the winding dissipates about 1.25 W in copper alone, using the typical DCR of 0.59 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    At Isat the part holds about 412 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    K-factor 345 means the flux swing is about 114 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Self-resonant frequency is 70 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    What This Family Is For

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Of the 23 values listed for HCM1A1305V2, this is the 3th, in a family covering 0.1 uH to 33 uH.

    Compared with its neighbours in the table, HCM1A1305V2-R47-R trades 4 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: alloy powder core, 13.8 x 12.9 mm body at 5.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 0.69 mOhm becomes roughly 1.06 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Confirm the qualification file covers the module-level test plan.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.

    Frequently Asked Questions

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products