Eaton HCM1A1305V2-R56-R: AEC-Q200 automotive power inductor, 0.56 uH ±20%, 29.5 A Irms, Isat 50 A, DCR 1.15 mOhm, 13.8 x 12.9 mm.
    • Product Details
    • Download

    Eaton HCM1A1305V2-R56-R 0.56 uH Shielded Automotive Inductor

    HCM1A1305V2-R56-R at a glance: AEC-Q200 automotive power inductor, 0.56 uH ±20%, 29.5 A Irms, Isat 50 A (20% rolloff @ +25 °C), DCR 1.15 mOhm, 13.8 x 12.9 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCM1A1305V2-R56-R
    OCL (open circuit inductance)0.56 uH ±20%
    FLL minimum, at Isat0.36 uH
    Irms (DC, 40 °C rise)29.5 A
    Isat (20% rolloff @ +25 °C)50 A
    DCR typical @ +20 °C1.15 mOhm
    DCR maximum @ +20 °C1.33 mOhm
    SRF typical57 MHz
    K-factor (Bp-p = K x L x dI)202, Bp-p in Gauss
    Package13.8 x 12.9 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10904

    Outline Drawing

    HCM1A1305V2-R56-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10904: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.

    Copper loss at the rated current works out to roughly 1 W from a typical DCR of 1.15 mOhm at 29.5 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    At Isat the part holds about 700 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    With K = 202, a peak-to-peak ripple of one amp produces roughly 113 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 57 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Where This Series Fits

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    In the HCM1A1305V2 line-up this part is number 5 of 23 by inductance, between 0.1 uH and 33 uH.

    The next value up in the same family, HCM1A1305V2-R68-R, gives 0.68 uH at 30 A and DCR 1.15 mOhm: the extra inductance costs about 14 A of rated current.

    • Core material: alloy powder core, 13.8 x 12.9 mm body at 5.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 1.33 mOhm becomes roughly 2.04 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.

    Frequently Asked Questions

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    What does AEC-Q200 cover?
    The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.