Eaton HCM1A1305V3-R47-R 0.47 uH Shielded Automotive Inductor
Eaton HCM1A1305V3-R47-R 0.47 uH Shielded Automotive Inductor

Eaton HCM1A1305V3-R47-R 0.47 uH Shielded Automotive Inductor

Share
Eaton HCM1A1305V3-R47-R: AEC-Q200 automotive power inductor, 0.47 uH ±20%, 44 A Irms, Isat 50 A, DCR 0.7 mOhm, 13.8 x 12.9 mm.
    • Product Details
    • Download

    Eaton HCM1A1305V3-R47-R 0.47 uH Shielded Automotive Inductor

    HCM1A1305V3-R47-R at a glance: AEC-Q200 automotive power inductor, 0.47 uH ±20%, 44 A Irms, Isat 50 A (20% rolloff @ +25 °C), DCR 0.7 mOhm, 13.8 x 12.9 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A1305V3-R47-R
    OCL (open circuit inductance)0.47 uH ±20%
    FLL minimum, at Isat0.3 uH
    Irms (DC, 40 °C rise)44 A
    Isat (20% rolloff @ +25 °C)50 A
    DCR typical @ +20 °C0.7 mOhm
    DCR maximum @ +20 °C0.85 mOhm
    SRF typical58 MHz
    K-factor (Bp-p = K x L x dI)367, Bp-p in Gauss
    Package13.8 x 12.9 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1488

    Mechanical Drawing

    HCM1A1305V3-R47-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1488: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    Copper loss at the rated current works out to roughly 1.35 W from a typical DCR of 0.7 mOhm at 44 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    The core stores roughly 588 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 367 means the flux swing is about 172 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Self-resonant frequency is 58 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    What This Family Is For

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Of the 23 values listed for HCM1A1305V3, this is the 4th, in a family covering 0.1 uH to 33 uH.

    Compared with its neighbours in the table, HCM1A1305V3-R56-R trades 16.5 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: alloy powder core, 13.8 x 12.9 mm body at 5.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 0.85 mOhm becomes roughly 1.3 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Confirm the qualification file covers the module-level test plan.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products