Eaton HCM1A1305V3-R56-R: AEC-Q200 automotive power inductor, 0.56 uH ±20%, 29.5 A Irms, Isat 50 A, DCR 1.15 mOhm, 13.8 x 12.9 mm.
    • Product Details
    • Download

    Eaton HCM1A1305V3-R56-R AEC-Q200 Inductor 0.56 uH, Isat 50 A

    HCM1A1305V3-R56-R at a glance: AEC-Q200 automotive power inductor, 0.56 uH ±20%, 29.5 A Irms, Isat 50 A (20% rolloff @ +25 °C), DCR 1.15 mOhm, 13.8 x 12.9 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1A1305V3-R56-R
    OCL (open circuit inductance)0.56 uH ±20%
    FLL minimum, at Isat0.36 uH
    Irms (DC, 40 °C rise)29.5 A
    Isat (20% rolloff @ +25 °C)50 A
    DCR typical @ +20 °C1.15 mOhm
    DCR maximum @ +20 °C1.33 mOhm
    SRF typical57 MHz
    K-factor (Bp-p = K x L x dI)239, Bp-p in Gauss
    Package13.8 x 12.9 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1488

    Dimensions and Pad Layout

    HCM1A1305V3-R56-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1488: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.

    Copper loss at the rated current works out to roughly 1 W from a typical DCR of 1.15 mOhm at 29.5 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Energy storage at the saturation current is around 700 uJ, the number that connects the inductance and the current rating into a single transient figure.

    With K = 239, a peak-to-peak ripple of one amp produces roughly 134 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 57 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    What This Family Is For

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    The HCM1A1305V3 family spans 0.1 uH to 33 uH; this row sits at position 5 of 23.

    Compared with its neighbours in the table, HCM1A1305V3-R68-R trades 14 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: alloy powder core, 13.8 x 12.9 mm body at 5.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 1.33 mOhm becomes roughly 2.04 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Confirm the qualification file covers the module-level test plan.
    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Check Isat and DCR at the hot corner, not at +20 °C.

    Frequently Asked Questions

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.