Eaton HCM1A1307V2-1R2-R AEC-Q200 Inductor 1.2 uH, Isat 30 A
Eaton HCM1A1307V2-1R2-R AEC-Q200 Inductor 1.2 uH, Isat 30 A

Eaton HCM1A1307V2-1R2-R AEC-Q200 Inductor 1.2 uH, Isat 30 A

Share
Eaton HCM1A1307V2-1R2-R: AEC-Q200 automotive power inductor, 1.2 uH ±20%, 22.5 A Irms, Isat 30 A, DCR 1.78 mOhm, 13.8 x 12.9 mm.
    • Product Details
    • Download

    Eaton HCM1A1307V2-1R2-R AEC-Q200 Inductor 1.2 uH, Isat 30 A

    HCM1A1307V2-1R2-R at a glance: AEC-Q200 automotive power inductor, 1.2 uH ±20%, 22.5 A Irms, Isat 30 A (20% rolloff @ +25 °C), DCR 1.78 mOhm, 13.8 x 12.9 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A1307V2-1R2-R
    OCL (open circuit inductance)1.2 uH ±20%
    FLL minimum, at Isat0.76 uH
    Irms (DC, 40 °C rise)22.5 A
    Isat (20% rolloff @ +25 °C)30 A
    DCR typical @ +20 °C1.78 mOhm
    DCR maximum @ +20 °C2.1 mOhm
    SRF typical34 MHz
    K-factor (Bp-p = K x L x dI)117, Bp-p in Gauss
    Package13.8 x 12.9 mm
    Height6.5 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10905

    Mechanical Dimensions & Pad Layout

    HCM1A1307V2-1R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10905: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    At the rated 22.5 A the winding dissipates about 0.901 W in copper alone, using the typical DCR of 1.78 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    The core stores roughly 540 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    With K = 117, a peak-to-peak ripple of one amp produces roughly 140 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 34 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Where This Series Fits

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Of the 20 values listed for HCM1A1307V2, this is the 5th, in a family covering 0.22 uH to 56 uH.

    One step down the table, HCM1A1307V2-1R0-R, sits at 1.0 uH with 28 A and 1.49 mOhm – the lower inductance buys about 7 A of extra current in the same body.

    • Core material: alloy powder core, 13.8 x 12.9 mm body at 6.5 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 2.1 mOhm becomes roughly 3.21 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Verify the part marking for revision traceability in production.
    • Verify the qualification and the mounting process match the assembly line.

    Frequently Asked Questions

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products