Eaton HCM1A1307V2-3R3-R: AEC-Q200 automotive power inductor, 3.3 uH ±20%, 16.5 A Irms, Isat 18 A, DCR 3.55 mOhm, 13.8 x 12.9 mm.
    • Product Details
    • Download

    Eaton HCM1A1307V2-3R3-R AEC-Q200 Inductor 3.3 uH, Isat 18 A

    HCM1A1307V2-3R3-R at a glance: AEC-Q200 automotive power inductor, 3.3 uH ±20%, 16.5 A Irms, Isat 18 A (20% rolloff @ +25 °C), DCR 3.55 mOhm, 13.8 x 12.9 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A1307V2-3R3-R
    OCL (open circuit inductance)3.3 uH ±20%
    FLL minimum, at Isat2.11 uH
    Irms (DC, 40 °C rise)16.5 A
    Isat (20% rolloff @ +25 °C)18 A
    DCR typical @ +20 °C3.55 mOhm
    DCR maximum @ +20 °C4.1 mOhm
    SRF typical18 MHz
    K-factor (Bp-p = K x L x dI)90, Bp-p in Gauss
    Package13.8 x 12.9 mm
    Height6.5 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10905

    Dimensions and Pad Layout

    HCM1A1307V2-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10905: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    Copper loss at the rated current works out to roughly 0.966 W from a typical DCR of 3.55 mOhm at 16.5 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    At Isat the part holds about 535 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    K-factor 90 means the flux swing is about 297 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Self-resonant frequency is 18 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    What This Family Is For

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A1307V2 family this is value 9 of 20, in a range that runs from 0.22 uH to 56 uH.

    The next value up in the same family, HCM1A1307V2-4R7-R, gives 4.7 uH at 13 A and DCR 6.25 mOhm: the extra inductance costs about 5.5 A of rated current.

    • Core material: alloy powder core, 13.8 x 12.9 mm body at 6.5 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 4.1 mOhm becomes roughly 6.28 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Verify the qualification and the mounting process match the assembly line.
    • Verify the part marking for revision traceability in production.
    • Check Isat and DCR at the hot corner, not at +20 °C.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.