Eaton HCM1A1307V3-1R0-R 1.0 uH Shielded Automotive Inductor
Eaton HCM1A1307V3-1R0-R 1.0 uH Shielded Automotive Inductor

Eaton HCM1A1307V3-1R0-R 1.0 uH Shielded Automotive Inductor

Share
Eaton HCM1A1307V3-1R0-R: AEC-Q200 automotive power inductor, 1.0 uH ±20%, 28 A Irms, Isat 34 A, DCR 1.49 mOhm, 13.8 x 12.9 mm.
    • Product Details
    • Download

    Eaton HCM1A1307V3-1R0-R 1.0 uH Shielded Automotive Inductor

    HCM1A1307V3-1R0-R at a glance: AEC-Q200 automotive power inductor, 1.0 uH ±20%, 28 A Irms, Isat 34 A (20% rolloff @ +25 °C), DCR 1.49 mOhm, 13.8 x 12.9 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A1307V3-1R0-R
    OCL (open circuit inductance)1.0 uH ±20%
    FLL minimum, at Isat0.64 uH
    Irms (DC, 40 °C rise)28 A
    Isat (20% rolloff @ +25 °C)34 A
    DCR typical @ +20 °C1.49 mOhm
    DCR maximum @ +20 °C1.75 mOhm
    SRF typical43 MHz
    K-factor (Bp-p = K x L x dI)192, Bp-p in Gauss
    Package13.8 x 12.9 mm
    Height6.5 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1489

    Dimensions and Pad Layout

    HCM1A1307V3-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1489: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    At the rated 28 A the winding dissipates about 1.17 W in copper alone, using the typical DCR of 1.49 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    At Isat the part holds about 578 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    With K = 192, a peak-to-peak ripple of one amp produces roughly 192 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 43 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Where This Series Fits

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    In the HCM1A1307V3 line-up this part is number 4 of 20 by inductance, between 0.22 uH and 56 uH.

    One step down the table, HCM1A1307V3-R47-R, sits at 0.47 uH with 43 A and 0.73 mOhm – the lower inductance buys about 20.5 A of extra current in the same body.

    • Core material: alloy powder core, 13.8 x 12.9 mm body at 6.5 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 1.75 mOhm becomes roughly 2.68 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Verify the part marking for revision traceability in production.
    • Verify the qualification and the mounting process match the assembly line.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products