Eaton HCM1A1307V3-1R8-R 1.8 uH AEC-Q200 Inductor, 19 A
Eaton HCM1A1307V3-1R8-R 1.8 uH AEC-Q200 Inductor, 19 A

Eaton HCM1A1307V3-1R8-R 1.8 uH AEC-Q200 Inductor, 19 A

Share
Eaton HCM1A1307V3-1R8-R: AEC-Q200 automotive power inductor, 1.8 uH ±20%, 19 A Irms, Isat 24 A, DCR 2.55 mOhm, 13.8 x 12.9 mm.
    • Product Details
    • Download

    Eaton HCM1A1307V3-1R8-R 1.8 uH AEC-Q200 Inductor, 19 A

    HCM1A1307V3-1R8-R at a glance: AEC-Q200 automotive power inductor, 1.8 uH ±20%, 19 A Irms, Isat 24 A (20% rolloff @ +25 °C), DCR 2.55 mOhm, 13.8 x 12.9 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A1307V3-1R8-R
    OCL (open circuit inductance)1.8 uH ±20%
    FLL minimum, at Isat1.15 uH
    Irms (DC, 40 °C rise)19 A
    Isat (20% rolloff @ +25 °C)24 A
    DCR typical @ +20 °C2.55 mOhm
    DCR maximum @ +20 °C2.94 mOhm
    SRF typical31 MHz
    K-factor (Bp-p = K x L x dI)260, Bp-p in Gauss
    Package13.8 x 12.9 mm
    Height6.5 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1489

    Dimensions and Pad Layout

    HCM1A1307V3-1R8-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1489: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.

    Copper loss at the rated current works out to roughly 0.921 W from a typical DCR of 2.55 mOhm at 19 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    At Isat the part holds about 518 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    K-factor 260 means the flux swing is about 468 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Self-resonant frequency is 31 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Where This Series Fits

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    The HCM1A1307V3 family spans 0.22 uH to 56 uH; this row sits at position 7 of 20.

    One step down the table, HCM1A1307V3-1R5-R, sits at 1.5 uH with 21 A and 2.04 mOhm – the lower inductance buys about 2.5 A of extra current in the same body.

    • Core material: alloy powder core, 13.8 x 12.9 mm body at 6.5 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 2.94 mOhm becomes roughly 4.5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Confirm the qualification file covers the module-level test plan.
    • Check the hot-corner saturation margin against the worst-case load step.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products