Eaton HCM1A1307V3-330-R 33 uH AEC-Q200 Inductor, 5 A
Eaton HCM1A1307V3-330-R 33 uH AEC-Q200 Inductor, 5 A

Eaton HCM1A1307V3-330-R 33 uH AEC-Q200 Inductor, 5 A

Share
Eaton HCM1A1307V3-330-R: AEC-Q200 automotive power inductor, 33 uH ±20%, 5 A Irms, Isat 7.5 A, DCR 40.8 mOhm, 13.8 x 12.9 mm.
    • Product Details
    • Download

    Eaton HCM1A1307V3-330-R 33 uH AEC-Q200 Inductor, 5 A

    HCM1A1307V3-330-R at a glance: AEC-Q200 automotive power inductor, 33 uH ±20%, 5 A Irms, Isat 7.5 A (20% rolloff @ +25 °C), DCR 40.8 mOhm, 13.8 x 12.9 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A1307V3-330-R
    OCL (open circuit inductance)33 uH ±20%
    FLL minimum, at Isat21 uH
    Irms (DC, 40 °C rise)5 A
    Isat (20% rolloff @ +25 °C)7.5 A
    DCR typical @ +20 °C40.8 mOhm
    DCR maximum @ +20 °C45 mOhm
    SRF typical4.5 MHz
    K-factor (Bp-p = K x L x dI)74, Bp-p in Gauss
    Package13.8 x 12.9 mm
    Height6.5 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1489

    Mechanical Drawing

    HCM1A1307V3-330-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1489: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    Copper loss at the rated current works out to roughly 1.02 W from a typical DCR of 40.8 mOhm at 5 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    The core stores roughly 928 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 74 means the flux swing is about 2,442 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Self-resonant frequency is 4.5 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    What This Family Is For

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    In the HCM1A1307V3 line-up this part is number 19 of 20 by inductance, between 0.22 uH and 56 uH.

    One step down the table, HCM1A1307V3-220-R, sits at 22 uH with 6 A and 28.8 mOhm – the lower inductance buys about 2 A of extra current in the same body.

    • Core material: alloy powder core, 13.8 x 12.9 mm body at 6.5 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 45 mOhm becomes roughly 68.9 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check the hot-corner saturation margin against the worst-case load step.
    • Verify the qualification and the mounting process match the assembly line.
    • Check the hot-corner saturation margin against the worst-case load step.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products