Eaton HCM1A1307V3-R22-R AEC-Q200 Inductor 0.22 uH, Isat 100 A
Eaton HCM1A1307V3-R22-R AEC-Q200 Inductor 0.22 uH, Isat 100 A

Eaton HCM1A1307V3-R22-R AEC-Q200 Inductor 0.22 uH, Isat 100 A

Share
Eaton HCM1A1307V3-R22-R: AEC-Q200 automotive power inductor, 0.22 uH ±20%, 52 A Irms, Isat 100 A, DCR 0.46 mOhm, 13.8 x 12.9 mm.
    • Product Details
    • Download

    Eaton HCM1A1307V3-R22-R AEC-Q200 Inductor 0.22 uH, Isat 100 A

    HCM1A1307V3-R22-R at a glance: AEC-Q200 automotive power inductor, 0.22 uH ±20%, 52 A Irms, Isat 100 A (20% rolloff @ +25 °C), DCR 0.46 mOhm, 13.8 x 12.9 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A1307V3-R22-R
    OCL (open circuit inductance)0.22 uH ±20%
    FLL minimum, at Isat0.14 uH
    Irms (DC, 40 °C rise)52 A
    Isat (20% rolloff @ +25 °C)100 A
    DCR typical @ +20 °C0.46 mOhm
    DCR maximum @ +20 °C0.6 mOhm
    SRF typical135 MHz
    K-factor (Bp-p = K x L x dI)298, Bp-p in Gauss
    Package13.8 x 12.9 mm
    Height6.5 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1489

    Dimensions and Pad Layout

    HCM1A1307V3-R22-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1489: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    This is the automotive version of the molded high-current inductor. The body is a molded powder core, the winding is shielded by the magnetic material itself, and the operating range runs to +155 °C. It is the part that goes on the DC-DC stages of body electronics, ADAS modules and infotainment head units.

    Copper loss at the rated current works out to roughly 1.24 W from a typical DCR of 0.46 mOhm at 52 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Energy storage at the saturation current is around 1,100 uJ, the number that connects the inductance and the current rating into a single transient figure.

    With K = 298, a peak-to-peak ripple of one amp produces roughly 65.6 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 135 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Where This Series Fits

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    The HCM1A1307V3 family spans 0.22 uH to 56 uH; this row sits at position 1 of 20.

    Compared with its neighbours in the table, HCM1A1307V3-R33-R trades 0 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: alloy powder core, 13.8 x 12.9 mm body at 6.5 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 0.6 mOhm becomes roughly 0.918 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Verify the qualification and the mounting process match the assembly line.
    • Confirm the qualification file covers the module-level test plan.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.

    Frequently Asked Questions

    What does AEC-Q200 cover?
    The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products