Eaton HCM1A1707V2-3R3-R: AEC-Q200 automotive power inductor, 3.3 uH ±20%, 19.5 A Irms, Isat 28 A, DCR 3 mOhm, 17.45 x 17.15 mm.
    • Product Details
    • Download

    Eaton HCM1A1707V2-3R3-R 3.3 uH Automotive Power Inductor

    HCM1A1707V2-3R3-R at a glance: AEC-Q200 automotive power inductor, 3.3 uH ±20%, 19.5 A Irms, Isat 28 A (20% rolloff @ +25 °C), DCR 3 mOhm, 17.45 x 17.15 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1A1707V2-3R3-R
    OCL (open circuit inductance)3.3 uH ±20%
    FLL minimum, at Isat2.11 uH
    Irms (DC, 40 °C rise)19.5 A
    Isat (20% rolloff @ +25 °C)28 A
    DCR typical @ +20 °C3 mOhm
    DCR maximum @ +20 °C3.27 mOhm
    SRF typical15 MHz
    K-factor (Bp-p = K x L x dI)80, Bp-p in Gauss
    Package17.45 x 17.15 mm
    Height7.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10906

    Mechanical Drawing

    HCM1A1707V2-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10906: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.

    At the rated 19.5 A the winding dissipates about 1.14 W in copper alone, using the typical DCR of 3 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    The core stores roughly 1,294 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 80 means the flux swing is about 264 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Self-resonant frequency is 15 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    What This Family Is For

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A1707V2 family this is value 4 of 13, in a range that runs from 1 uH to 68 uH.

    Compared with its neighbours in the table, HCM1A1707V2-4R7-R trades 4 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: alloy powder core, 17.45 x 17.15 mm body at 7.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 3.27 mOhm becomes roughly 5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Confirm the qualification file covers the module-level test plan.
    • Verify the part marking for revision traceability in production.

    Frequently Asked Questions

    Why do V2 and V3 parts exist?
    They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products