Eaton HCM1A2213V2-R47-R AEC-Q200 Inductor 0.47 uH, Isat 100 A
Eaton HCM1A2213V2-R47-R AEC-Q200 Inductor 0.47 uH, Isat 100 A

Eaton HCM1A2213V2-R47-R AEC-Q200 Inductor 0.47 uH, Isat 100 A

Share
Eaton HCM1A2213V2-R47-R: AEC-Q200 automotive power inductor, 0.47 uH ±20%, 66 A Irms, Isat 100 A, DCR 0.4 mOhm, 22.78 x 22.3 mm.
    • Product Details
    • Download

    Eaton HCM1A2213V2-R47-R AEC-Q200 Inductor 0.47 uH, Isat 100 A

    HCM1A2213V2-R47-R at a glance: AEC-Q200 automotive power inductor, 0.47 uH ±20%, 66 A Irms, Isat 100 A (20% rolloff @ +25 °C), DCR 0.4 mOhm, 22.78 x 22.3 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1A2213V2-R47-R
    OCL (open circuit inductance)0.47 uH ±20%
    FLL minimum, at Isat0.3 uH
    Irms (DC, 40 °C rise)66 A
    Isat (20% rolloff @ +25 °C)100 A
    DCR typical @ +20 °C0.4 mOhm
    DCR maximum @ +20 °C0.5 mOhm
    SRF typical52 MHz
    K-factor (Bp-p = K x L x dI)111, Bp-p in Gauss
    Package22.78 x 22.3 mm
    Height13.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10907

    Mechanical Dimensions & Pad Layout

    HCM1A2213V2-R47-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10907: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    Copper loss at the rated current works out to roughly 1.74 W from a typical DCR of 0.4 mOhm at 66 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Stored energy at Isat is about 2,350 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    The K-factor of 111 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 52.2 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Self-resonant frequency is 52 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    What This Family Is For

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    The HCM1A2213V2 family spans 0.47 uH to 100 uH; this row sits at position 1 of 14.

    Compared with its neighbours in the table, HCM1A2213V2-1R0-R trades 0 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: alloy powder core, 22.78 x 22.3 mm body at 13.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 0.5 mOhm becomes roughly 0.765 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check the hot-corner saturation margin against the worst-case load step.
    • Confirm the qualification file covers the module-level test plan.
    • Confirm the qualification file covers the module-level test plan.

    Frequently Asked Questions

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What does AEC-Q200 cover?
    The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.