Eaton HCM1A4020V2-100-R: AEC-Q200 automotive power inductor, 10.0 uH ±20%, 1.6 A Irms, Isat 2.2 A, DCR 245 mOhm, 4.75 x 4.45 mm.
    • Product Details
    • Download

    Eaton HCM1A4020V2-100-R 10.0 uH AEC-Q200 Inductor, 1.6 A

    HCM1A4020V2-100-R at a glance: AEC-Q200 automotive power inductor, 10.0 uH ±20%, 1.6 A Irms, Isat 2.2 A (20% rolloff @ +25 °C), DCR 245 mOhm, 4.75 x 4.45 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A4020V2-100-R
    OCL (open circuit inductance)10.0 uH ±20%
    FLL minimum, at Isat5.6 uH
    Irms (DC, 40 °C rise)1.6 A
    Isat (20% rolloff @ +25 °C)2.2 A
    DCR typical @ +20 °C245 mOhm
    DCR maximum @ +20 °C281 mOhm
    SRF typical17 MHz
    K-factor (Bp-p = K x L x dI)342, Bp-p in Gauss
    Package4.75 x 4.45 mm
    Height2.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10908

    Mechanical Drawing

    HCM1A4020V2-100-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10908: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.

    With 245 mOhm typical, the I-squared-R loss at the full 1.6 A rating is about 0.627 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Stored energy at Isat is about 24.2 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    With K = 342, a peak-to-peak ripple of one amp produces roughly 3,420 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 17 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Series Positioning

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Of the 15 values listed for HCM1A4020V2, this is the 14th, in a family covering 0.1 uH to 15 uH.

    The next value up in the same family, HCM1A4020V2-150-R, gives 15.0 uH at 1.3 A and DCR 320 mOhm: the extra inductance costs about 0.4 A of rated current.

    • Core material: alloy powder core, 4.75 x 4.45 mm body at 2.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 281 mOhm becomes roughly 430 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Confirm the qualification file covers the module-level test plan.
    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.

    Frequently Asked Questions

    What does AEC-Q200 cover?
    The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.

    Why do V2 and V3 parts exist?
    They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products