| Parameter | Value |
|---|---|
| Orderable part number | HCM1A4020V2-R33-R |
| OCL (open circuit inductance) | 0.33 uH ±20% |
| FLL minimum, at Isat | 0.185 uH |
| Irms (DC, 40 °C rise) | 8.5 A |
| Isat (20% rolloff @ +25 °C) | 12 A |
| DCR typical @ +20 °C | 7.5 mOhm |
| DCR maximum @ +20 °C | 9 mOhm |
| SRF typical | 140 MHz |
| K-factor (Bp-p = K x L x dI) | 1,906, Bp-p in Gauss |
| Package | 4.75 x 4.45 mm |
| Height | 2.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10908 |

Drawing reproduced from Eaton Technical Data 10908: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.
With 7.5 mOhm typical, the I-squared-R loss at the full 8.5 A rating is about 0.542 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
Energy storage at the saturation current is around 23.8 uJ, the number that connects the inductance and the current rating into a single transient figure.
K-factor 1,906 means the flux swing is about 629 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
Self-resonant frequency is 140 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
The HCM1A4020V2 family spans 0.1 uH to 15 uH; this row sits at position 3 of 15.
One step down the table, HCM1A4020V2-R22-R, sits at 0.22 uH with 11 A and 5.5 mOhm – the lower inductance buys about 3.7 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 9 mOhm becomes roughly 13.8 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
What is the self-resonant frequency used for?