| Parameter | Value |
|---|---|
| Orderable part number | HCM1A4020V3-R56-R |
| OCL (open circuit inductance) | 0.56 uH ±20% |
| FLL minimum, at Isat | 0.314 uH |
| Irms (DC, 40 °C rise) | 7.3 A |
| Isat (20% rolloff @ +25 °C) | 10 A |
| DCR typical @ +20 °C | 12 mOhm |
| DCR maximum @ +20 °C | 15 mOhm |
| SRF typical | 95 MHz |
| K-factor (Bp-p = K x L x dI) | 2,007, Bp-p in Gauss |
| Package | 4.75 x 4.45 mm |
| Height | 2.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1495 |

Drawing reproduced from Eaton Technical Data ELX1495: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.
Copper loss at the rated current works out to roughly 0.639 W from a typical DCR of 12 mOhm at 7.3 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
Stored energy at Isat is about 28 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
K-factor 2,007 means the flux swing is about 1,124 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
Self-resonant frequency is 95 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
The HCM1A4020V3 family spans 0.1 uH to 15 uH; this row sits at position 5 of 15.
One step down the table, HCM1A4020V3-R47-R, sits at 0.47 uH with 7.3 A and 10.5 mOhm – the lower inductance buys about 0.6 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 15 mOhm becomes roughly 23 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd