Eaton HCMA0503-1R5-R 1.5 uH Automotive High-Current Inductor
Eaton HCMA0503-1R5-R 1.5 uH Automotive High-Current Inductor

Eaton HCMA0503-1R5-R 1.5 uH Automotive High-Current Inductor

Share
Eaton HCMA0503-1R5-R: AEC-Q200 high-current inductor, 1.5 uH ±20%, 7.5 A Irms, Isat 7 A, DCR 17.1 mOhm, 5.5 x 5.3 mm.
    • Product Details
    • Download

    Eaton HCMA0503-1R5-R 1.5 uH Automotive High-Current Inductor

    HCMA0503-1R5-R at a glance: AEC-Q200 high-current inductor, 1.5 uH ±20%, 7.5 A Irms, Isat 7 A (20% rolloff @ +25 °C), DCR 17.1 mOhm, 5.5 x 5.3 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCMA0503-1R5-R
    OCL (open circuit inductance)1.5 uH ±20%
    FLL minimum, at Isat0.96 uH
    Irms (DC, 40 °C rise)7.5 A
    Isat (20% rolloff @ +25 °C)7 A
    DCR typical @ +20 °C17.1 mOhm
    DCR maximum @ +20 °C18.5 mOhm
    K-factor (Bp-p = K x L x dI)393, Bp-p in Gauss
    Package5.5 x 5.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10248

    Outline Drawing

    HCMA0503-1R5-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10248: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    This is the high-current member of the automotive molded family. Where the standard automotive parts top out at a few tens of amps, this one is built for the main DC-DC stage: thicker winding, larger body, and a saturation current that scales with it.

    With 17.1 mOhm typical, the I-squared-R loss at the full 7.5 A rating is about 0.962 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    At Isat the part holds about 36.8 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    K-factor 393 means the flux swing is about 590 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Positioning in the Range

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    In the HCMA0503 line-up this part is number 6 of 14 by inductance, between 0.2 uH and 22 uH.

    The next value up in the same family, HCMA0503-2R2-R, gives 2.2 uH at 6.8 A and DCR 22.5 mOhm: the extra inductance costs about 3.3 A of rated current.

    • Core material: iron powder core, 5.5 x 5.3 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning con­ trollers (hvac); doors, window lift and seat control.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 18.5 mOhm becomes roughly 26.1 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Confirm the terminal spacing against the rail voltage.
    • Check the current derating at the maximum ambient of the module.
    • Confirm the terminal spacing against the rail voltage.

    Frequently Asked Questions

    What is the difference between Irms and Isat here?
    Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.

    Can it be used on a 48 V rail?
    The inductance and current ratings suit 48 V converters, but the insulation system and creepage are board-level concerns. Check the terminal spacing and conformal coating against the rail voltage.

    What is the difference between Irms and Isat here?
    Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products