| Parameter | Value |
|---|---|
| Orderable part number | HCMA0503-4R7-R |
| OCL (open circuit inductance) | 4.7 uH ±20% |
| FLL minimum, at Isat | 3 uH |
| Irms (DC, 40 °C rise) | 4.5 A |
| Isat (20% rolloff @ +25 °C) | 5.5 A |
| DCR typical @ +20 °C | 54 mOhm |
| DCR maximum @ +20 °C | 60 mOhm |
| K-factor (Bp-p = K x L x dI) | 226, Bp-p in Gauss |
| Package | 5.5 x 5.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10248 |

Drawing reproduced from Eaton Technical Data 10248: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded powder core, shielded, AEC-Q200, +125 °C: the part is aimed at automotive DC-DC converters and motor-drive front ends where the inductor carries the full load current and the board has to pass EMC without a shield can.
With 54 mOhm typical, the I-squared-R loss at the full 4.5 A rating is about 1.09 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
At Isat the part holds about 71.1 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
The K-factor of 226 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 1,062 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
Within the HCMA0503 family this is value 9 of 14, in a range that runs from 0.2 uH to 22 uH.
Compared with its neighbours in the table, HCMA0503-5R6-R trades 1.25 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 60 mOhm becomes roughly 84.8 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
How does this differ from the commercial HCM part?
Same molded construction and similar body sizes, but automotive qualified, characterised to +125 °C, and wound for higher current in the larger sizes. The electrical rows are not interchangeable.
Can it be used on a 48 V rail?
The inductance and current ratings suit 48 V converters, but the insulation system and creepage are board-level concerns. Check the terminal spacing and conformal coating against the rail voltage.
What current can it carry continuously?
The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.
Shenzhen Gaorunxin Technology Co., Ltd