Eaton HCMA0503-6R8-R 6.8 uH AEC-Q200 Inductor, 2.6 A
Eaton HCMA0503-6R8-R 6.8 uH AEC-Q200 Inductor, 2.6 A

Eaton HCMA0503-6R8-R 6.8 uH AEC-Q200 Inductor, 2.6 A

Share
Eaton HCMA0503-6R8-R: AEC-Q200 high-current inductor, 6.8 uH ±20%, 2.6 A Irms, Isat 3.8 A, DCR 91 mOhm, 5.5 x 5.3 mm.
    • Product Details
    • Download

    Eaton HCMA0503-6R8-R 6.8 uH AEC-Q200 Inductor, 2.6 A

    HCMA0503-6R8-R at a glance: AEC-Q200 high-current inductor, 6.8 uH ±20%, 2.6 A Irms, Isat 3.8 A (20% rolloff @ +25 °C), DCR 91 mOhm, 5.5 x 5.3 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCMA0503-6R8-R
    OCL (open circuit inductance)6.8 uH ±20%
    FLL minimum, at Isat4.4 uH
    Irms (DC, 40 °C rise)2.6 A
    Isat (20% rolloff @ +25 °C)3.8 A
    DCR typical @ +20 °C91 mOhm
    DCR maximum @ +20 °C99 mOhm
    K-factor (Bp-p = K x L x dI)172, Bp-p in Gauss
    Package5.5 x 5.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10248

    Outline Drawing

    HCMA0503-6R8-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10248: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Molded powder core, shielded, AEC-Q200, +125 °C: the part is aimed at automotive DC-DC converters and motor-drive front ends where the inductor carries the full load current and the board has to pass EMC without a shield can.

    With 91 mOhm typical, the I-squared-R loss at the full 2.6 A rating is about 0.615 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    At Isat the part holds about 49.1 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    With K = 172, a peak-to-peak ripple of one amp produces roughly 1,170 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Positioning in the Range

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    Within the HCMA0503 family this is value 11 of 14, in a range that runs from 0.2 uH to 22 uH.

    The next value up in the same family, HCMA0503-100-R, gives 10 uH at 2.75 A and DCR 122 mOhm: the extra inductance costs about 1.5 A of rated current.

    • Core material: iron powder core, 5.5 x 5.3 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning con­ trollers (hvac); doors, window lift and seat control.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 99 mOhm becomes roughly 140 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Compare against the commercial HCM row of the same size before substituting.
    • Confirm the terminal spacing against the rail voltage.
    • Verify the shielding against the EMC plan for the board.

    Frequently Asked Questions

    What is the difference between Irms and Isat here?
    Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.

    What current can it carry continuously?
    The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.

    Can it be used on a 48 V rail?
    The inductance and current ratings suit 48 V converters, but the insulation system and creepage are board-level concerns. Check the terminal spacing and conformal coating against the rail voltage.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products