| Parameter | Value |
|---|---|
| Orderable part number | HCMA0503-R75-R |
| OCL (open circuit inductance) | 0.75 uH ±20% |
| FLL minimum, at Isat | 0.48 uH |
| Irms (DC, 40 °C rise) | 11.3 A |
| Isat (20% rolloff @ +25 °C) | 9.7 A |
| DCR typical @ +20 °C | 8.5 mOhm |
| DCR maximum @ +20 °C | 9.35 mOhm |
| K-factor (Bp-p = K x L x dI) | 801, Bp-p in Gauss |
| Package | 5.5 x 5.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10248 |

Drawing reproduced from Eaton Technical Data 10248: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified high-current inductor on a molded powder core, rated to +125 °C. The construction is chosen for current density: the winding is pressed into the magnetic material, so there is no bobbin wasting window area and the DCR stays low for the body size.
With 8.5 mOhm typical, the I-squared-R loss at the full 11.3 A rating is about 1.08 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
At Isat the part holds about 35.3 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
With K = 801, a peak-to-peak ripple of one amp produces roughly 601 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
The HCMA0503 family spans 0.2 uH to 22 uH; this row sits at position 4 of 14.
Compared with its neighbours in the table, HCMA0503-1R0-R trades 1.9 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 9.35 mOhm becomes roughly 13.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
What is the difference between Irms and Isat here?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
What is the difference between Irms and Isat here?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
Can it be used on a 48 V rail?
The inductance and current ratings suit 48 V converters, but the insulation system and creepage are board-level concerns. Check the terminal spacing and conformal coating against the rail voltage.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd