Eaton HCMA0703-220-R: AEC-Q200 high-current inductor, 22 uH ±20%, 2.3 A Irms, Isat 3 A, DCR 135 mOhm, 7.4 x 7 mm.
    • Product Details
    • Download

    Eaton HCMA0703-220-R 22 uH AEC-Q200 Inductor, 2.3 A

    HCMA0703-220-R at a glance: AEC-Q200 high-current inductor, 22 uH ±20%, 2.3 A Irms, Isat 3 A (20% rolloff @ +25 °C), DCR 135 mOhm, 7.4 x 7 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCMA0703-220-R
    OCL (open circuit inductance)22 uH ±20%
    FLL minimum, at Isat14.1 uH
    Irms (DC, 40 °C rise)2.3 A
    Isat (20% rolloff @ +25 °C)3 A
    DCR typical @ +20 °C135 mOhm
    DCR maximum @ +20 °C149 mOhm
    K-factor (Bp-p = K x L x dI)83, Bp-p in Gauss
    Package7.4 x 7 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10282

    Dimensions and Pad Layout

    HCMA0703-220-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10282: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    The family takes the molded construction used on the commercial high-current parts and applies the automotive qualification and temperature range. Soft saturation and low DCR are the two properties that matter on a 48 V or 12 V rail carrying tens of amps.

    At the rated 2.3 A the winding dissipates about 0.714 W in copper alone, using the typical DCR of 135 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Energy storage at the saturation current is around 99 uJ, the number that connects the inductance and the current rating into a single transient figure.

    K-factor 83 means the flux swing is about 1,826 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Where This Series Fits

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    The HCMA0703 family spans 0.15 uH to 33 uH; this row sits at position 14 of 15.

    One step down the table, HCMA0703-100-R, sits at 10 uH with 3.2 A and 71 mOhm – the lower inductance buys about 1.4 A of extra current in the same body.

    • Core material: iron powder core, 7.4 x 7 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tai lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 149 mOhm becomes roughly 210 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Check the current derating at the maximum ambient of the module.
    • Check the terminal spacing against the rail voltage and the coating scheme.
    • Check the terminal spacing against the rail voltage and the coating scheme.

    Frequently Asked Questions

    What is the difference between Irms and Isat here?
    Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.

    Is this part suitable for a 48 V rail?
    The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.

    What is the difference between Irms and Isat here?
    Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products