| Parameter | Value |
|---|---|
| Orderable part number | HCMA0703-330-R |
| OCL (open circuit inductance) | 33 uH ±20% |
| FLL minimum, at Isat | 19.8 uH |
| Irms (DC, 40 °C rise) | 1.8 A |
| Isat (20% rolloff @ +25 °C) | 2.2 A |
| DCR typical @ +20 °C | 220 mOhm |
| DCR maximum @ +20 °C | 242 mOhm |
| K-factor (Bp-p = K x L x dI) | 76, Bp-p in Gauss |
| Package | 7.4 x 7 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10282 |

Drawing reproduced from Eaton Technical Data 10282: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is the high-current member of the automotive molded family. Where the standard automotive parts top out at a few tens of amps, this one is built for the main DC-DC stage: thicker winding, larger body, and a saturation current that scales with it.
Copper loss at the rated current works out to roughly 0.713 W from a typical DCR of 220 mOhm at 1.8 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Energy storage at the saturation current is around 79.9 uJ, the number that connects the inductance and the current rating into a single transient figure.
K-factor 76 means the flux swing is about 2,508 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
Of the 15 values listed for HCMA0703, this is the 15th, in a family covering 0.15 uH to 33 uH.
Compared with its neighbours in the table, HCMA0703-220-R trades 0 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 242 mOhm becomes roughly 342 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
Is it shielded?
Yes – the winding is enclosed in the molded powder core, which keeps the external field low enough for dense automotive boards.
Is this part suitable for a 48 V rail?
The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.
What is the difference between Irms and Isat here?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd