Eaton HCMA0703-3R3-R 3.3 uH Automotive High-Current Inductor
Eaton HCMA0703-3R3-R 3.3 uH Automotive High-Current Inductor

Eaton HCMA0703-3R3-R 3.3 uH Automotive High-Current Inductor

Share
Eaton HCMA0703-3R3-R: AEC-Q200 high-current inductor, 3.3 uH ±20%, 6 A Irms, Isat 13.5 A, DCR 28 mOhm, 7.4 x 7 mm.
    • Product Details
    • Download

    Eaton HCMA0703-3R3-R 3.3 uH Automotive High-Current Inductor

    HCMA0703-3R3-R at a glance: AEC-Q200 high-current inductor, 3.3 uH ±20%, 6 A Irms, Isat 13.5 A (20% rolloff @ +25 °C), DCR 28 mOhm, 7.4 x 7 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCMA0703-3R3-R
    OCL (open circuit inductance)3.3 uH ±20%
    FLL minimum, at Isat1.98 uH
    Irms (DC, 40 °C rise)6 A
    Isat (20% rolloff @ +25 °C)13.5 A
    DCR typical @ +20 °C28 mOhm
    DCR maximum @ +20 °C30 mOhm
    K-factor (Bp-p = K x L x dI)252, Bp-p in Gauss
    Package7.4 x 7 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10282

    Dimensions and Pad Layout

    HCMA0703-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10282: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    This is the high-current member of the automotive molded family. Where the standard automotive parts top out at a few tens of amps, this one is built for the main DC-DC stage: thicker winding, larger body, and a saturation current that scales with it.

    With 28 mOhm typical, the I-squared-R loss at the full 6 A rating is about 1.01 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Energy storage at the saturation current is around 301 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The K-factor of 252 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 832 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Positioning in the Range

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    In the HCMA0703 line-up this part is number 9 of 15 by inductance, between 0.15 uH and 33 uH.

    Compared with its neighbours in the table, HCMA0703-4R7-R trades 2.5 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 7.4 x 7 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tai lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 30 mOhm becomes roughly 42.4 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Confirm the terminal spacing against the rail voltage.
    • Check the terminal spacing against the rail voltage and the coating scheme.
    • Check the terminal spacing against the rail voltage and the coating scheme.

    Frequently Asked Questions

    Is this part suitable for a 48 V rail?
    The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.

    Can it be used on a 48 V rail?
    The inductance and current ratings suit 48 V converters, but the insulation system and creepage are board-level concerns. Check the terminal spacing and conformal coating against the rail voltage.

    What current can it carry continuously?
    The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.