| Parameter | Value |
|---|---|
| Orderable part number | HCMA0703-R47-R |
| OCL (open circuit inductance) | 0.47 uH ±20% |
| FLL minimum, at Isat | 0.28 uH |
| Irms (DC, 40 °C rise) | 17.5 A |
| Isat (20% rolloff @ +25 °C) | 26 A |
| DCR typical @ +20 °C | 4 mOhm |
| DCR maximum @ +20 °C | 4.2 mOhm |
| K-factor (Bp-p = K x L x dI) | 580, Bp-p in Gauss |
| Package | 7.4 x 7 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10282 |

Drawing reproduced from Eaton Technical Data 10282: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The family takes the molded construction used on the commercial high-current parts and applies the automotive qualification and temperature range. Soft saturation and low DCR are the two properties that matter on a 48 V or 12 V rail carrying tens of amps.
Copper loss at the rated current works out to roughly 1.23 W from a typical DCR of 4 mOhm at 17.5 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
The core stores roughly 159 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
K-factor 580 means the flux swing is about 273 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
The HCMA0703 family spans 0.15 uH to 33 uH; this row sits at position 3 of 15.
Compared with its neighbours in the table, HCMA0703-R68-R trades 7.5 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 4.2 mOhm becomes roughly 5.93 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
How does this differ from the commercial HCM part?
Same molded construction and similar body sizes, but automotive qualified, characterised to +125 °C, and wound for higher current in the larger sizes. The electrical rows are not interchangeable.
Is this part suitable for a 48 V rail?
The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.
Is this part suitable for a 48 V rail?
The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.
Shenzhen Gaorunxin Technology Co., Ltd