Eaton HCMA0703-R68-R: AEC-Q200 high-current inductor, 0.68 uH ±20%, 15.5 A Irms, Isat 25 A, DCR 5 mOhm, 7.4 x 7 mm.
    • Product Details
    • Download

    Eaton HCMA0703-R68-R AEC-Q200 Inductor 0.68 uH, Isat 25 A

    HCMA0703-R68-R at a glance: AEC-Q200 high-current inductor, 0.68 uH ±20%, 15.5 A Irms, Isat 25 A (20% rolloff @ +25 °C), DCR 5 mOhm, 7.4 x 7 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCMA0703-R68-R
    OCL (open circuit inductance)0.68 uH ±20%
    FLL minimum, at Isat0.41 uH
    Irms (DC, 40 °C rise)15.5 A
    Isat (20% rolloff @ +25 °C)25 A
    DCR typical @ +20 °C5 mOhm
    DCR maximum @ +20 °C5.5 mOhm
    K-factor (Bp-p = K x L x dI)455, Bp-p in Gauss
    Package7.4 x 7 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10282

    Dimensions and Pad Layout

    HCMA0703-R68-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10282: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    The family takes the molded construction used on the commercial high-current parts and applies the automotive qualification and temperature range. Soft saturation and low DCR are the two properties that matter on a 48 V or 12 V rail carrying tens of amps.

    The DCR figure of 5 mOhm is what sets the efficiency: at 15.5 A the winding drops about 0.077 mV and dissipates 1.2 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Energy storage at the saturation current is around 212 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The K-factor of 455 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 309 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Series Positioning

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    Of the 15 values listed for HCMA0703, this is the 4th, in a family covering 0.15 uH to 33 uH.

    One step down the table, HCMA0703-R47-R, sits at 0.47 uH with 17.5 A and 4 mOhm – the lower inductance buys about 4.5 A of extra current in the same body.

    • Core material: iron powder core, 7.4 x 7 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tai lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 5.5 mOhm becomes roughly 7.77 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Size the saturation margin at the maximum ambient the module will see.
    • Check the current derating at the maximum ambient of the module.
    • Check the current derating at the maximum ambient of the module.

    Frequently Asked Questions

    Is this part suitable for a 48 V rail?
    The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.

    What current can it carry continuously?
    The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.

    What current can it carry continuously?
    The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products