Eaton HCMA1104-220-R AEC-Q200 Inductor 22 uH, Isat 5.5 A
Eaton HCMA1104-220-R AEC-Q200 Inductor 22 uH, Isat 5.5 A

Eaton HCMA1104-220-R AEC-Q200 Inductor 22 uH, Isat 5.5 A

Share
Eaton HCMA1104-220-R: AEC-Q200 high-current inductor, 22 uH ±20%, 5 A Irms, Isat 5.5 A, DCR 60 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCMA1104-220-R AEC-Q200 Inductor 22 uH, Isat 5.5 A

    HCMA1104-220-R at a glance: AEC-Q200 high-current inductor, 22 uH ±20%, 5 A Irms, Isat 5.5 A (20% rolloff @ +25 °C), DCR 60 mOhm, 11.5 x 10.3 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCMA1104-220-R
    OCL (open circuit inductance)22 uH ±20%
    FLL minimum, at Isat12.3 uH
    Irms (DC, 40 °C rise)5 A
    Isat (20% rolloff @ +25 °C)5.5 A
    DCR typical @ +20 °C60 mOhm
    DCR maximum @ +20 °C66 mOhm
    K-factor (Bp-p = K x L x dI)92, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10349

    Outline Drawing

    HCMA1104-220-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10349: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    AEC-Q200 qualified high-current inductor on a molded powder core, rated to +125 °C. The construction is chosen for current density: the winding is pressed into the magnetic material, so there is no bobbin wasting window area and the DCR stays low for the body size.

    At the rated 5 A the winding dissipates about 1.5 W in copper alone, using the typical DCR of 60 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    At Isat the part holds about 333 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    The K-factor of 92 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 2,024 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    What This Family Is For

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    Within the HCMA1104 family this is value 12 of 12, in a range that runs from 0.2 uH to 22 uH.

    The next value up in the same family, HCMA1104-100-R, gives 10 uH at 7.5 A and DCR 27 mOhm: the extra inductance costs about 0 A of rated current.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 4.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tai lamps and interior lighting; heating ventilation and air conditioning con- trollers (hvac); doors, window lift and seat control.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 66 mOhm becomes roughly 93.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Confirm the terminal spacing against the rail voltage.
    • Check the current derating at the maximum ambient of the module.
    • Confirm the terminal spacing against the rail voltage.

    Frequently Asked Questions

    How does this differ from the commercial HCM part?
    Same molded construction and similar body sizes, but automotive qualified, characterised to +125 °C, and wound for higher current in the larger sizes. The electrical rows are not interchangeable.

    How does this differ from the commercial HCM part?
    Same molded construction and similar body sizes, but automotive qualified, characterised to +125 °C, and wound for higher current in the larger sizes. The electrical rows are not interchangeable.

    What current can it carry continuously?
    The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.