Eaton HCMA1104-2R2-R AEC-Q200 Inductor 2.2 uH, Isat 18 A
Eaton HCMA1104-2R2-R AEC-Q200 Inductor 2.2 uH, Isat 18 A

Eaton HCMA1104-2R2-R AEC-Q200 Inductor 2.2 uH, Isat 18 A

Share
Eaton HCMA1104-2R2-R: AEC-Q200 high-current inductor, 2.2 uH ±20%, 12 A Irms, Isat 18 A, DCR 6 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCMA1104-2R2-R AEC-Q200 Inductor 2.2 uH, Isat 18 A

    HCMA1104-2R2-R at a glance: AEC-Q200 high-current inductor, 2.2 uH ±20%, 12 A Irms, Isat 18 A (20% rolloff @ +25 °C), DCR 6 mOhm, 11.5 x 10.3 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCMA1104-2R2-R
    OCL (open circuit inductance)2.2 uH ±20%
    FLL minimum, at Isat1.23 uH
    Irms (DC, 40 °C rise)12 A
    Isat (20% rolloff @ +25 °C)18 A
    DCR typical @ +20 °C6 mOhm
    DCR maximum @ +20 °C7 mOhm
    K-factor (Bp-p = K x L x dI)253, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10349

    Dimensions and Pad Layout

    HCMA1104-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10349: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    This is the high-current member of the automotive molded family. Where the standard automotive parts top out at a few tens of amps, this one is built for the main DC-DC stage: thicker winding, larger body, and a saturation current that scales with it.

    With 6 mOhm typical, the I-squared-R loss at the full 12 A rating is about 0.864 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    At Isat the part holds about 356 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    With K = 253, a peak-to-peak ripple of one amp produces roughly 557 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Positioning in the Range

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    Within the HCMA1104 family this is value 8 of 12, in a range that runs from 0.2 uH to 22 uH.

    One step down the table, HCMA1104-1R5-R, sits at 1.5 uH with 16 A and 3.8 mOhm – the lower inductance buys about 6 A of extra current in the same body.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 4.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tai lamps and interior lighting; heating ventilation and air conditioning con- trollers (hvac); doors, window lift and seat control.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 7 mOhm becomes roughly 9.89 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Confirm the terminal spacing against the rail voltage.
    • Size the saturation margin at the maximum ambient the module will see.
    • Verify the shielding against the EMC plan for the board.

    Frequently Asked Questions

    Can it be used on a 48 V rail?
    The inductance and current ratings suit 48 V converters, but the insulation system and creepage are board-level concerns. Check the terminal spacing and conformal coating against the rail voltage.

    What current can it carry continuously?
    The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.

    Can it be used on a 48 V rail?
    The inductance and current ratings suit 48 V converters, but the insulation system and creepage are board-level concerns. Check the terminal spacing and conformal coating against the rail voltage.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message