| Parameter | Value |
|---|---|
| Orderable part number | HCMA1305-1R0-R |
| OCL (open circuit inductance) | 1.00 uH ±20% |
| FLL minimum, at Isat | 0.64 uH |
| Irms (DC, 40 °C rise) | 29 A |
| Isat (20% rolloff @ +25 °C) | 50 A |
| DCR typical @ +20 °C | 2.1 mOhm |
| DCR maximum @ +20 °C | 2.42 mOhm |
| K-factor (Bp-p = K x L x dI) | 275, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10277 |

Drawing reproduced from Eaton Technical Data 10277: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The family takes the molded construction used on the commercial high-current parts and applies the automotive qualification and temperature range. Soft saturation and low DCR are the two properties that matter on a 48 V or 12 V rail carrying tens of amps.
The DCR figure of 2.1 mOhm is what sets the efficiency: at 29 A the winding drops about 0.061 mV and dissipates 1.77 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
Energy storage at the saturation current is around 1,250 uJ, the number that connects the inductance and the current rating into a single transient figure.
The K-factor of 275 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 275 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
The HCMA1305 family spans 0.1 uH to 33 uH; this row sits at position 8 of 21.
One step down the table, HCMA1305-R82-R, sits at 0.82 uH with 31 A and 1.4 mOhm – the lower inductance buys about 8 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2.42 mOhm becomes roughly 3.42 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
Is it shielded?
Yes – the winding is enclosed in the molded powder core, which keeps the external field low enough for dense automotive boards.
What is the difference between Irms and Isat here?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
What current can it carry continuously?
The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.