Eaton HCMA1305-5R6-R 5.60 uH Automotive High-Current Inductor
Eaton HCMA1305-5R6-R 5.60 uH Automotive High-Current Inductor

Eaton HCMA1305-5R6-R 5.60 uH Automotive High-Current Inductor

Share
Eaton HCMA1305-5R6-R: AEC-Q200 high-current inductor, 5.60 uH ±20%, 11.5 A Irms, Isat 22 A, DCR 12 mOhm, 13.8 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCMA1305-5R6-R 5.60 uH Automotive High-Current Inductor

    HCMA1305-5R6-R at a glance: AEC-Q200 high-current inductor, 5.60 uH ±20%, 11.5 A Irms, Isat 22 A (20% rolloff @ +25 °C), DCR 12 mOhm, 13.8 x 12.5 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCMA1305-5R6-R
    OCL (open circuit inductance)5.60 uH ±20%
    FLL minimum, at Isat3.58 uH
    Irms (DC, 40 °C rise)11.5 A
    Isat (20% rolloff @ +25 °C)22 A
    DCR typical @ +20 °C12 mOhm
    DCR maximum @ +20 °C13.8 mOhm
    K-factor (Bp-p = K x L x dI)142, Bp-p in Gauss
    Package13.8 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10277

    Mechanical Dimensions & Pad Layout

    HCMA1305-5R6-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10277: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    This is the high-current member of the automotive molded family. Where the standard automotive parts top out at a few tens of amps, this one is built for the main DC-DC stage: thicker winding, larger body, and a saturation current that scales with it.

    With 12 mOhm typical, the I-squared-R loss at the full 11.5 A rating is about 1.59 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Stored energy at Isat is about 1,355 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    With K = 142, a peak-to-peak ripple of one amp produces roughly 795 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Series Positioning

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    In the HCMA1305 line-up this part is number 14 of 21 by inductance, between 0.1 uH and 33 uH.

    The next value up in the same family, HCMA1305-6R8-R, gives 6.80 uH at 11 A and DCR 13 mOhm: the extra inductance costs about 1 A of rated current.

    • Core material: iron powder core, 13.8 x 12.5 mm body at 5.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 13.8 mOhm becomes roughly 19.5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Compare against the commercial HCM row of the same size before substituting.
    • Confirm the terminal spacing against the rail voltage.
    • Verify the shielding against the EMC plan for the board.

    Frequently Asked Questions

    Can it be used on a 48 V rail?
    The inductance and current ratings suit 48 V converters, but the insulation system and creepage are board-level concerns. Check the terminal spacing and conformal coating against the rail voltage.

    What current can it carry continuously?
    The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.

    Is it shielded?
    Yes – the winding is enclosed in the molded powder core, which keeps the external field low enough for dense automotive boards.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products