| Parameter | Value |
|---|---|
| Orderable part number | HCMA1305-R22-R |
| OCL (open circuit inductance) | 0.22 uH ±20% |
| FLL minimum, at Isat | 0.14 uH |
| Irms (DC, 40 °C rise) | 51 A |
| Isat (20% rolloff @ +25 °C) | 110 A |
| DCR typical @ +20 °C | 0.63 mOhm |
| DCR maximum @ +20 °C | 0.72 mOhm |
| K-factor (Bp-p = K x L x dI) | 843, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10277 |

Drawing reproduced from Eaton Technical Data 10277: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is the high-current member of the automotive molded family. Where the standard automotive parts top out at a few tens of amps, this one is built for the main DC-DC stage: thicker winding, larger body, and a saturation current that scales with it.
The DCR figure of 0.63 mOhm is what sets the efficiency: at 51 A the winding drops about 0.032 mV and dissipates 1.64 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
Energy storage at the saturation current is around 1,331 uJ, the number that connects the inductance and the current rating into a single transient figure.
With K = 843, a peak-to-peak ripple of one amp produces roughly 186 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
Within the HCMA1305 family this is value 2 of 21, in a range that runs from 0.1 uH to 33 uH.
Compared with its neighbours in the table, HCMA1305-R33-R trades 13 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.72 mOhm becomes roughly 1.02 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
Is this part suitable for a 48 V rail?
The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.
What is the difference between Irms and Isat here?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
Can it be used on a 48 V rail?
The inductance and current ratings suit 48 V converters, but the insulation system and creepage are board-level concerns. Check the terminal spacing and conformal coating against the rail voltage.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd