| Parameter | Value |
|---|---|
| Orderable part number | HCMA1305-R47-R |
| OCL (open circuit inductance) | 0.47 uH ±20% |
| FLL minimum, at Isat | 0.3 uH |
| Irms (DC, 40 °C rise) | 38 A |
| Isat (20% rolloff @ +25 °C) | 65 A |
| DCR typical @ +20 °C | 0.8 mOhm |
| DCR maximum @ +20 °C | 0.92 mOhm |
| K-factor (Bp-p = K x L x dI) | 506, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10277 |

Drawing reproduced from Eaton Technical Data 10277: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The family takes the molded construction used on the commercial high-current parts and applies the automotive qualification and temperature range. Soft saturation and low DCR are the two properties that matter on a 48 V or 12 V rail carrying tens of amps.
With 0.8 mOhm typical, the I-squared-R loss at the full 38 A rating is about 1.16 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
The core stores roughly 993 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
With K = 506, a peak-to-peak ripple of one amp produces roughly 238 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
Of the 21 values listed for HCMA1305, this is the 4th, in a family covering 0.1 uH to 33 uH.
The next value up in the same family, HCMA1305-R56-R, gives 0.56 uH at 36 A and DCR 1.15 mOhm: the extra inductance costs about 6 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.92 mOhm becomes roughly 1.3 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
What current can it carry continuously?
The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.
What current can it carry continuously?
The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.
Is it shielded?
Yes – the winding is enclosed in the molded powder core, which keeps the external field low enough for dense automotive boards.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd