Eaton HCMA1707-2R2-R 2.2 uH AEC-Q200 Inductor, 37 A
Eaton HCMA1707-2R2-R 2.2 uH AEC-Q200 Inductor, 37 A

Eaton HCMA1707-2R2-R 2.2 uH AEC-Q200 Inductor, 37 A

Share
Eaton HCMA1707-2R2-R: AEC-Q200 high-current inductor, 2.2 uH ±20%, 37 A Irms, Isat 34 A, DCR 2.15 mOhm, 17.5 x 17.2 mm.
    • Product Details
    • Download

    Eaton HCMA1707-2R2-R 2.2 uH AEC-Q200 Inductor, 37 A

    HCMA1707-2R2-R at a glance: AEC-Q200 high-current inductor, 2.2 uH ±20%, 37 A Irms, Isat 34 A (20% rolloff @ +25 °C), DCR 2.15 mOhm, 17.5 x 17.2 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCMA1707-2R2-R
    OCL (open circuit inductance)2.2 uH ±20%
    FLL minimum, at Isat1.41 uH
    Irms (DC, 40 °C rise)37 A
    Isat (20% rolloff @ +25 °C)34 A
    DCR typical @ +20 °C2.15 mOhm
    DCR maximum @ +20 °C2.5 mOhm
    K-factor (Bp-p = K x L x dI)103, Bp-p in Gauss
    Package17.5 x 17.2 mm
    Height7.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10296

    Mechanical Dimensions & Pad Layout

    HCMA1707-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10296: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    AEC-Q200 qualified high-current inductor on a molded powder core, rated to +125 °C. The construction is chosen for current density: the winding is pressed into the magnetic material, so there is no bobbin wasting window area and the DCR stays low for the body size.

    At the rated 37 A the winding dissipates about 2.94 W in copper alone, using the typical DCR of 2.15 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Stored energy at Isat is about 1,272 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    K-factor 103 means the flux swing is about 227 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    What This Family Is For

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    In the HCMA1707 line-up this part is number 2 of 11 by inductance, between 1.5 uH and 68 uH.

    One step down the table, HCMA1707-1R5-R, sits at 1.5 uH with 40 A and 1.85 mOhm – the lower inductance buys about 13 A of extra current in the same body.

    • Core material: iron powder core, 17.5 x 17.2 mm body at 7.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tai lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2.5 mOhm becomes roughly 3.53 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Size the saturation margin at the maximum ambient the module will see.
    • Compare against the commercial HCM row of the same size before substituting.
    • Check the current derating at the maximum ambient of the module.

    Frequently Asked Questions

    What is the difference between Irms and Isat here?
    Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.

    Is this part suitable for a 48 V rail?
    The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.

    Is this part suitable for a 48 V rail?
    The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.