| Parameter | Value |
|---|---|
| Orderable part number | HCMA1707-680-R |
| OCL (open circuit inductance) | 68 uH ±20% |
| FLL minimum, at Isat | 43.5 uH |
| Irms (DC, 40 °C rise) | 5.2 A |
| Isat (20% rolloff @ +25 °C) | 6.5 A |
| DCR typical @ +20 °C | 74 mOhm |
| DCR maximum @ +20 °C | 85 mOhm |
| K-factor (Bp-p = K x L x dI) | 20, Bp-p in Gauss |
| Package | 17.5 x 17.2 mm |
| Height | 7.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10296 |

Drawing reproduced from Eaton Technical Data 10296: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The family takes the molded construction used on the commercial high-current parts and applies the automotive qualification and temperature range. Soft saturation and low DCR are the two properties that matter on a 48 V or 12 V rail carrying tens of amps.
With 74 mOhm typical, the I-squared-R loss at the full 5.2 A rating is about 2 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
The core stores roughly 1,436 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
K-factor 20 means the flux swing is about 1,360 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
Of the 11 values listed for HCMA1707, this is the 11th, in a family covering 1.5 uH to 68 uH.
Compared with its neighbours in the table, HCMA1707-470-R trades 0 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 85 mOhm becomes roughly 120 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
What is the difference between Irms and Isat here?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
What is the difference between Irms and Isat here?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
Is this part suitable for a 48 V rail?
The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.