Eaton HCP0605-R10-R Iron Powder Inductor 0.095 uH, Isat 20 A
Eaton HCP0605-R10-R Iron Powder Inductor 0.095 uH, Isat 20 A

Eaton HCP0605-R10-R Iron Powder Inductor 0.095 uH, Isat 20 A

Share
Eaton HCP0605-R10-R: iron powder high-current inductor, 0.095 uH ±15%, 53 A Irms, Isat 20 A, DCR 0.4 mOhm, 5.3 x 6.1 mm.
    • Product Details
    • Download

    Eaton HCP0605-R10-R Iron Powder Inductor 0.095 uH, Isat 20 A

    HCP0605-R10-R at a glance: iron powder high-current inductor, 0.095 uH ±15%, 53 A Irms, Isat 20 A (30% rolloff @ +25 °C), DCR 0.4 mOhm, 5.3 x 6.1 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCP0605-R10-R
    OCL (open circuit inductance)0.095 uH ±15%
    FLL minimum, at Isat0.06 uH
    Irms (DC, 40 °C rise)53 A
    Isat (30% rolloff @ +25 °C)20 A
    DCR typical @ +20 °C0.4 mOhm
    K-factor (Bp-p = K x L x dI)120, Bp-p in Gauss
    Package5.3 x 6.1 mm
    Height4.95 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4368

    Mechanical Drawing

    HCP0605-R10-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4368: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    Iron powder core in a shielded surface-mount body: the material gives a soft saturation curve, so inductance falls gradually with current rather than dropping off a cliff. The part is aimed at VRM and point-of-load stages where the inductor spends its working life part-way up the saturation curve.

    The DCR figure of 0.4 mOhm is what sets the efficiency: at 53 A the winding drops about 0.021 mV and dissipates 1.12 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The Isat column is 30% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    The core stores roughly 19 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 120 means the flux swing is about 11.4 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Positioning in the Range

    The HCP family is the iron powder, shielded, high-current range for VRM and point-of-load work. It covers modest inductance values at high DC bias, with the soft saturation curve that iron powder is chosen for.

    The HCP0605 family spans 0.095 uH to 0.095 uH; this row sits at position 1 of 1.

    • Core material: iron powder core, 5.3 x 6.1 mm body at 4.95 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; desktop and server vrms and evrds; point-of-load (pol) modules; notebook regulators; data networking and storage systems.
    • Iron powder has a soft saturation curve but a lower permeability than ferrite, so the turns count – and therefore the DCR – is higher for the same inductance.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.4 mOhm becomes roughly 0.565 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: at high DC bias the inductance is well below OCL. Use the inductance-versus-current curve for the ripple calculation, not the headline value.

    • Read the inductance at the actual DC bias from the curve before sizing ripple.
    • Confirm the K-factor against the ripple amplitude for the core-loss estimate.
    • Confirm the K-factor against the ripple amplitude for the core-loss estimate.

    Frequently Asked Questions

    Why iron powder rather than ferrite?
    Iron powder saturates at a much higher flux density, so a small core can carry a large DC bias. The price is lower permeability, which means more turns and higher DCR for the same inductance.

    Is it shielded?
    The powder core encloses the winding, so the fringing field is limited. It is suitable for multiphase layouts where inductors sit side by side.

    What core loss should I expect?
    Read the core-loss curve at the flux amplitude implied by the K-factor and the ripple, at the switching frequency. Core loss is quoted per unit volume, so compare curves rather than single numbers.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products