Eaton HCP0704-3R3-R 3.30 uH Iron Powder Inductor, 6 A
Eaton HCP0704-3R3-R 3.30 uH Iron Powder Inductor, 6 A

Eaton HCP0704-3R3-R 3.30 uH Iron Powder Inductor, 6 A

Share
Eaton HCP0704-3R3-R: iron powder high-current inductor, 3.30 uH ±25%, 6 A Irms, Isat 9.5 A, DCR 25 mOhm, 6.8 x 6.8 mm.
    • Product Details
    • Download

    Eaton HCP0704-3R3-R 3.30 uH Iron Powder Inductor, 6 A

    HCP0704-3R3-R at a glance: iron powder high-current inductor, 3.30 uH ±25%, 6 A Irms, Isat 9.5 A (20% rolloff @ +25 °C), DCR 25 mOhm, 6.8 x 6.8 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCP0704-3R3-R
    OCL (open circuit inductance)3.30 uH ±25%
    FLL minimum, at Isat2.31 uH
    Irms (DC, 40 °C rise)6 A
    Isat (20% rolloff @ +25 °C)9.5 A
    DCR typical @ +20 °C25 mOhm
    K-factor (Bp-p = K x L x dI)150, Bp-p in Gauss
    Package6.8 x 6.8 mm
    Height4.2 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4348

    Mechanical Drawing

    HCP0704-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4348: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    The core here is iron powder, pressed into a shielded body. Iron powder has lower permeability than ferrite but far higher saturation flux density, which is why this family is used where the DC bias is large and the inductance value is modest.

    Copper loss at the rated current works out to roughly 0.9 W from a typical DCR of 25 mOhm at 6 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Stored energy at Isat is about 149 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    With K = 150, a peak-to-peak ripple of one amp produces roughly 495 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    What This Family Is For

    The HCP family is the iron powder, shielded, high-current range for VRM and point-of-load work. It covers modest inductance values at high DC bias, with the soft saturation curve that iron powder is chosen for.

    Within the HCP0704 family this is value 6 of 7, in a range that runs from 0.4 uH to 4.7 uH.

    The next value up in the same family, HCP0704-4R7-R, gives 4.70 uH at 5 A and DCR 29.5 mOhm: the extra inductance costs about 2.5 A of rated current.

    • Core material: iron powder core, 6.8 x 6.8 mm body at 4.2 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; desktop and servers; base station equipment; notebook and laptop regulators; data networking and storage systems.
    • Iron powder has a soft saturation curve but a lower permeability than ferrite, so the turns count – and therefore the DCR – is higher for the same inductance.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 25 mOhm becomes roughly 38.3 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: at high DC bias the inductance is well below OCL. Use the inductance-versus-current curve for the ripple calculation, not the headline value.

    • Check the inductance at the operating bias, not the catalogue value.
    • Account for the lower permeability of iron powder in the turns count and DCR.
    • Read the inductance at the actual DC bias from the curve before sizing ripple.

    Frequently Asked Questions

    What does the K-factor tell me?
    It converts inductance and ripple current into flux swing: K times L times delta-I gives Bp-p. That amplitude is what the core-loss graph is plotted against.

    Is the saturation curve linear?
    No – it is deliberately soft. Inductance droops progressively above the rated current, which is why the ripple calculation should use the inductance at the actual bias, not the headline value.

    Is the saturation curve linear?
    No – it is deliberately soft. Inductance droops progressively above the rated current, which is why the ripple calculation should use the inductance at the actual bias, not the headline value.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products