Eaton HCP0704-R40-R 0.40 uH High-Current Inductor 3.2 mOhm
Eaton HCP0704-R40-R 0.40 uH High-Current Inductor 3.2 mOhm

Eaton HCP0704-R40-R 0.40 uH High-Current Inductor 3.2 mOhm

Share
Eaton HCP0704-R40-R: iron powder high-current inductor, 0.40 uH ±25%, 17 A Irms, Isat 27 A, DCR 3.2 mOhm, 6.8 x 6.8 mm.
    • Product Details
    • Download

    Eaton HCP0704-R40-R 0.40 uH High-Current Inductor 3.2 mOhm

    HCP0704-R40-R at a glance: iron powder high-current inductor, 0.40 uH ±25%, 17 A Irms, Isat 27 A (20% rolloff @ +25 °C), DCR 3.2 mOhm, 6.8 x 6.8 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCP0704-R40-R
    OCL (open circuit inductance)0.40 uH ±25%
    FLL minimum, at Isat0.28 uH
    Irms (DC, 40 °C rise)17 A
    Isat (20% rolloff @ +25 °C)27 A
    DCR typical @ +20 °C3.2 mOhm
    K-factor (Bp-p = K x L x dI)383, Bp-p in Gauss
    Package6.8 x 6.8 mm
    Height4.2 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4348

    Dimensions and Pad Layout

    HCP0704-R40-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4348: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    A shielded iron powder inductor for high-current switching stages. The distributed gap of the powder core spreads the stored energy through the volume, so the part handles a large DC component without local saturation, and the shielding keeps the fringing field small.

    The DCR figure of 3.2 mOhm is what sets the efficiency: at 17 A the winding drops about 0.054 mV and dissipates 0.925 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Energy storage at the saturation current is around 146 uJ, the number that connects the inductance and the current rating into a single transient figure.

    With K = 383, a peak-to-peak ripple of one amp produces roughly 153 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Positioning in the Range

    The HCP family is the iron powder, shielded, high-current range for VRM and point-of-load work. It covers modest inductance values at high DC bias, with the soft saturation curve that iron powder is chosen for.

    Within the HCP0704 family this is value 1 of 7, in a range that runs from 0.4 uH to 4.7 uH.

    Compared with its neighbours in the table, HCP0704-R60-R trades 0 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 6.8 x 6.8 mm body at 4.2 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; desktop and servers; base station equipment; notebook and laptop regulators; data networking and storage systems.
    • Iron powder has a soft saturation curve but a lower permeability than ferrite, so the turns count – and therefore the DCR – is higher for the same inductance.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 3.2 mOhm becomes roughly 4.9 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: at high DC bias the inductance is well below OCL. Use the inductance-versus-current curve for the ripple calculation, not the headline value.

    • Verify the footprint against the recommended pad layout.
    • Check the K-factor against the ripple amplitude to estimate core loss.
    • Check the K-factor against the ripple amplitude to estimate core loss.

    Frequently Asked Questions

    Why iron powder rather than ferrite?
    Iron powder saturates at a much higher flux density, so a small core can carry a large DC bias. The price is lower permeability, which means more turns and higher DCR for the same inductance.

    Is the part suitable for a high-frequency design?
    Iron powder suits the low-to-mid hundreds of kilohertz range. Above that the loss of the powder material rises faster than ferrite, so compare the loss curves before choosing.

    Is it shielded?
    The powder core encloses the winding, so the fringing field is limited. It is suitable for multiphase layouts where inductors sit side by side.